LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
70151-1339 SGE-125-0-2830 1000 OMRON 70151-1339 SGE-125-0-2830 1000
No PHOTO
OMRON 70151-1339 SGE-125-0-2830 1000
Power Supply: Model, S82J; Capacity, 25 W.
Easy-to-use DIN Rail Mounting Bracket for,
Power Supplies.
Mounts to the PFP-100N and PFP-100N2 DIN Rails.
Supports models S82J (100, 150-W models). Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0 OMRON 70151-1339 SGE-125-0-2830 1000. 1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h 70151-1339 SGE-125-0-2830 1000
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 OMRON 70151-1339 SGE-125-0-2830 1000.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry OMRON 70151-1339 SGE-125-0-2830 1000. Size: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:-- .
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance perfformance .
The connection method ccan be selected from a screw terminal and a PUSH-IN fastening terminal 70151-1339 SGE-125-0-2830 1000.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsiion Village (sold separately) connected to the computer after,
No power connection can be set 70151-1339 SGE-125-0-2830 1000.
It can be easily set by CS-Thermo (sold separately).
70151-1339 SGE-125-0-2830 1000 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=70151-1339 SGE-125-0-2830 1000&select=5


...more relevant model market price >>>>
Related products