Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped (Socket)/Straight (Plug).
Cable diameter: 6.0 mm dia.
No. of cable cores: 4.
Cable core cross sectional area: 0.5 mm.
Cable length: 5 m.
DC: Minimum order, 5.
UL-listed: Yes.
Water- and Environment-resistive FA OMRON 70132-1629 MS47SR-20-975-LCM10.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
70132-1629 MS47SR-20-975-LCM10
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available OMRON 70132-1629 MS47SR-20-975-LCM10.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified .
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.080 A; 60 Hz, 0.060 A .
Rated input: 50 Hz, 10 W ; 60 Hz, 9 W OMRON 70132-1629 MS47SR-20-975-LCM10.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3200 r/min.
Maximum flow rate: 50 Hz, 0.8 m3/min; 60 Hz, 0 . 9 m3/min.
Maximum static pressure: 50 Hz, 42.1 Pa; 60 Hz, 58.8 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUN/STOPP, alarm), interactive display PV/SV 70132-1629 MS47SR-20-975-LCM10.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation 70132-1629 MS47SR-20-975-LCM10.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
70132-1629 MS47SR-20-975-LCM10 Operation manual/Instructions/Model selection sample download link: