LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
70028-1079 MS4312C-AC1-30X-30R OMRON 70028-1079 MS4312C-AC1-30X-30R
No PHOTO
OMRON 70028-1079 MS4312C-AC1-30X-30R
Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 35 A, 200 to 480 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks OMRON 70028-1079 MS4312C-AC1-30X-30R.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting 70028-1079 MS4312C-AC1-30X-30R
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks OMRON 70028-1079 MS4312C-AC1-30X-30R.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track .
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Classification: Exclusive Models.
Description: Used for measuring surface temperatures.
Temperature range (See note 3.): -50°C to 250°C .
Element type: Pt100.
Conductor type: 3-conductor system OMRON 70028-1079 MS4312C-AC1-30X-30R.
Class: B.
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 39 .
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. I/O Cable (for I/O to Interface Racks) 1 m (L) CV500-CN122Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer .4.3 CX-Thermo) makes the proceess of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output 70028-1079 MS4312C-AC1-30X-30R.
Through the infrared port can be carried out from the frronnt of the communication 70028-1079 MS4312C-AC1-30X-30R.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.