Appearance: Round/Half-guard type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-H.
Output: SPST-NC.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia OMRON 44507-1260 MA-12AP11C3. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit
44507-1260 MA-12AP11C3
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts OMRON 44507-1260 MA-12AP11C3.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals .
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Optical system: Regular reflective.
Beam shape: Spot beam.
Sensing distance: 30±2 mm.
Resolution: 0.25 μm.
For the most recent information on models that have been,
certified for safety standards, refer to your OMRON website OMRON 44507-1260 MA-12AP11C3. Description: OS32C with side location cable entry.
Max. Operating Range (Safety Zone): 4m .
Remarks: CD-ROM (Configuration tool) OS supported: Windows 2000,
Windows XP (32-bit version, Service Pack 3 or later),
Windows Vista (32-bit version), Windows 7 (32-bit version/64-bit version),
For configuration tool version, refer to page 23.
Compact (104.5 mm), lightweight (1.3 kg),
and easy-to-install Safety Laser Scanner.
Provides a safety circuit of PLd/Safety Category 3 (ISO13849-1) without a,
dedicated controller.
Type 3 Safety Laser Scanner complies with IEC61496-1/-3.
70 sets of safety zone and warning zone combinations are available,
supporting complicated changes in working environments.
A safety radius up to 4 m and warning zone(s) radius up to 15 m can be set.
The minimum object resolution can be changed to 30, 40, 50 or 70 mm.
The response time is configurable from 80 ms to a maximum of 680 ms.
Reference Boundary Monitoring function prevents unauthorized changes in,
the scanner position.
Minimal down time, sensor block can be replaced without the need to reprogram. Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 2 notches.
Resetting method: Automatic.
Output: SPST-NO + SPST-NO.
Operating voltage: 100 VAC.
Illumination color: R (red); Y (yellow); G (green); AA (blue) .
Install in 22-ddia 44507-1260 MA-12AP11C3. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounttedd using either open-type (fork-type) or closed-type,
(round-type) crimp terminals 44507-1260 MA-12AP11C3.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
44507-1260 MA-12AP11C3 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=44507-1260 MA-12AP11C3&select=5