LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
3G3HV-PUZDAB72A0.5MH OMRON 3G3HV-PUZDAB72A0.5MH
No PHOTO
OMRON 3G3HV-PUZDAB72A0.5MH
Input type: DC current input.
Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with OMRON 3G3HV-PUZDAB72A0.5MH.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table 3G3HV-PUZDAB72A0.5MH
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations OMRON 3G3HV-PUZDAB72A0.5MH.
DeviSpecifications: Input, PNP (- common), 8 points .
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: Supplied from the communications connector.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting OMRON 3G3HV-PUZDAB72A0.5MH.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities .
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required for input devices such as sensors.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.
The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further pperformance improvement 3G3HV-PUZDAB72A0.5MH.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV 3G3HV-PUZDAB72A0.5MH.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
3G3HV-PUZDAB72A0.5MH Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=3G3HV-PUZDAB72A0.5MH&select=5