LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
3F88L-CR005C OMRON 3F88L-CR005C
No PHOTO
OMRON 3F88L-CR005C
Name: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4 OMRON 3F88L-CR005C.
Communications functions: Port C: RS-422,
From End Unit: Port A: RS-485.
Input type: No input 3F88L-CR005C
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application OMRON 3F88L-CR005C.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design .
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise OMRON 3F88L-CR005C.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages, undervoltages, phase sequence,
and phase loss for three-phase 3-wire or 4-wire power,
supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Output overvoltages and undervoltages using separate relays.
World-wide power specifications supported by one Unit (switchable).
Output status can be monitored using LED indicator. Cable Specifications: Spatter resistant Cables.
No. of connector poles: 4.
Cable connection direction: Straight.
No. of cable cores: 4.
Cable outer diameter: 6.6 mm dia.
Cable core cross-sectional area: 0.5 mm.
Cable length: 0.3 m.
DC: Model.
Minimum order: 10.
UL-listed: --.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 reequirements and eensure a,
94V-0 fire retardant rating 3F88L-CR005C.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnnector Assembly: Crimping, soldering, and screw-on 3F88L-CR005C.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
3F88L-CR005C Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=3F88L-CR005C&select=5


...more relevant model market price >>>>
Related products
OMRON
Cam positioner
3F88L-160
OMRON Cam positioner 3F88L-160
To achieve a more rapid, more advanced r
OMRON
Cam positioner
3F88L-162
OMRON Cam positioner 3F88L-162
To achieve a more rapid, more advanced r