Analog /PNP output type.
Display size: 5.7 inches.
Resolution: 320 x 240 pixels (QVGA).
LCD:TFT.
Color: 65536 color.
Ethernet interface: 1.
Serial port: 1.
CANopen interface: 1.
USB (host):1.
USB (equipment):1.
Built in DIO input: 12 points.
Built in DIO output: 6 points.
Built in AIO input: 4 points Proface PFXGP3450TADC.
Built in AIO output: 2 points.
Common DIO:2 point high speed counter (with synchronous output) pulse capture input
PFXGP3450TADC
Dedicated DIO:2 point pulse output, PWM output.
Expansion module EX module: none.
Expansion module CANopen module: 63 stations.
Controller memory size: EPROM 132KB FLASH (equivalent to 15000 steps (up to 60000 steps) Proface PFXGP3450TADC.
CANopen network
LT4000M supports data exchange with a variety of remote devices through the CANopen, easy to achieve economic and easy to use system design .
Can choose standard I/O module, also can choose action or control module and other more advanced products in complex application.
Compact size.
The volume is small but the display is fresh and bright, can create a rich and readable operation picture Proface PFXGP3450TADC.
The control function of the whole and the digital I/O, analog I/O, analog temperature input and USB, serial port and Ethernet communication interface .
Integrated design.
Adopt integrative design, compact structure,
When the installation is only required to open a hole in the panel 22mm.
The display module or the control module can be easily replaced when the fault is eliminated.
Flexible installation.
The control module can be installed on the DIN guide rail by using the split installation cable,
And the display module is installed in other locations.
Display module occupies a small space, even if the space is limited, but also can be flexible to install. A veneer, for the GP4000 series back loading models of full flush (white, 1)COM2 module is applicable for the isolation of COM2 through a variety of hosts and GP3000 connectionSpecifications: DC24/H (handheld) class models.
Emergency stop switch: red.
Display type: STN pseudo color LCD.
Display size: 5.7 inches.
Resolution: 320 x 240 pixels (QVGA).
Display color: 4096 color.
Backlight: white LED (back light lamp replacement: return to repair).
Brightness adjustment: 16 level adjustment can be carried out by touch panel.
Touch panel type: resistance type (analog).
Error visualization.
The controller is directly connected to the GP, and the key error information of the controller can be displayed on the GP by using the sample unit.
No need to open the control panel, through the PLC to monitor the GP program.
Through the data through the GP function, you can easily debug the ladder program and adjust the data due to changes in the production line by GP easily.
Can improve the efficiency of the 5 functions.
Using EX GP-Pro can easily create a clear picture and save the creation time.
Screen and logic programming software EX GP-Pro interface is very friendly,
The drag and drop feature makes the software interface easy to operate.
EX GP-Pro powerful features, such as 3D simulation components, image fonts and simulation functions,
Even beginners can easily and quickly grasp how to create a picture.
Providing operation and maintenance instructions through video mode, which can save maintenance cost.
The operation and maintenance instructions provided by the video mode can make any operator easy to master the operation method.
Easily upgrade.
GP/ST series supports GP series of all models of the screen data, including the first generation of the GP10 series.
GP product family to maintain the size of the opening of the panel compatibility, to facilitate easy replacement.
Rich sample images can reduce programming time.
Pro-face provides a large number of sample images and 3D parts,
So you can easily create a beautiful and intuitive picture, in order to save editing time. Data transmission using USB memory.
In the production site using USB memory can be easily transferred to the production line change and change the screen data.
Safety control function can minimize the problem of production site
Password management functions can be based on each operator or administrator password to enter the set level can be operated by the screen,
According to the function of the operator to set the password to enter the level.
In order to strengthen the management, the operator must enter the ID and the password to operate the equipment.
Use USB memory or CF card backup monthly and daily
Recording function using USB memory or CF card can easily improve the efficiency of daily and monthly.
The use of CSV data conversion function can be modified on the PLC GP settings.
Simulated running status on PC.
Use PC simulation function, do not need to transfer the picture to GP,
You cann check all the fuunctions of GP on the PC - including the screen operation, D script, logical script PFXGP3450TADC.
Remote operation and monitoring in the Office
In the office or other remote side can monitor the production site of the GP screen.
Without picturee eediting or programming, you can achieve real-time management and monitoring, and now, you can also provide more efficient remote maintenance control PFXGP3450TADC.
PFXGP3450TADC Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=PFXGP3450TADC&select=5