LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
Proface EXM-DDO16UK EXM-DDO16UK
Proface EXM-DDO16UK
Input voltage: DC24V.
Screen size: 10.4 inches.
Display type (resolution):65536 color TFT display LCD (VGA 640 x 480 pixels).
Touch panel type: analog resistance.
Memory: 32MB (internal memory), SRAM320KB (backup memory), SRAM64KB (variable area).
Ethernet interface: 1.
Serial port: RS-232C * 1, RS-422/485 * 1 Proface EXM-DDO16UK.
SD card slot (max 32GB):1.
USB interface: Type-A x (2) USB 1, Mini-B USB (2) x 1.
Replaceable battery: yes EXM-DDO16UK
Alarm analysis function block: yes.
Panel opening size:
Wide 259 x high 201mm (+1/0mm)
Panel thickness: 1.6-5mm, chamfer radius is less than R3.
Coating models: there.
Meet a number of standards to support a wide range of applications
The coating components are widely used in various working environments, and are in line with the international standards Proface EXM-DDO16UK.
Remote data acquisition and management.
Human machine interface, which is installed on the production machine,
With EX Microsoft software combined with Office Pro-Server and SQL and other standard PC software,
Can be simple and economical to establish a set of data management system, and effectively improve the quality of production and efficiency Proface EXM-DDO16UK. Use external output for the GP3000 series of auxiliary connectors (5 / sets).DIO model /PNP output type.
Display size: 5.7 inches.
Resolution: 320 x 240 pixels (QVGA).
LCD:TFT.
Color: 65536 color.
Ethernet interface: 1.
Serial port: 1.
CANopen interface: 1.
USB (host):1.
USB (equipment):1.
Built in DIO input: 20 points.
Built in DIO output: 10 points.
Built in AIO input: No.
Built in AIO output: No.
Common DIO:2 point high speed counter (with synchronous output) pulse capture input.
Dedicated DIO:2 point pulse output, PWM output.
Expansion module EX module: none.
Expansion module CANopen module: 63 stations.
Controller memory size: EPROM 132KB FLASH (equivalent to 15000 steps (up to 60000 steps).
Integrated design.
Adopt integrative design, compact structure,
When the installation is only required to open a hole in the panel 22mm.
The display module or the control module can be easily replaced when the fault is eliminated.
Flexible installation.
The control module can be installed on the DIN guide rail by using the split installation cable,
And the display module is installed in other locatiions EXM-DDO16UK.
Display module occupies a small space, even if the space is limited, but also can be flexible to install.
Compact size.
The volume is small but the display is fresh and bright, can create a rich and readable operation picture.

Thhe control function of the whole and the digital I/O, analog I/O, analog temperature input and USB, serial port and Ethernet communication interface EXM-DDO16UK.
EXM-DDO16UK Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=EXM-DDO16UK&select=5


...more relevant model market price >>>>
Related products
Proface
Input / output hybrid module
EXM-DMM24DRF
Proface Input / output hybrid module EXM-DMM24DRF
Input points: 16 points NPN/PNP type.
Proface
Input / output hybrid module
EXM-DMM8DRT
Proface Input / output hybrid module EXM-DMM8DRT
Input points: 4 point relay NPN/PNP typ
Proface
Input module
EXM-DDI8DT
Proface Input module EXM-DDI8DT
Input points: 8 points NPN/PNP type. E
Proface
output module
EXM-DRA16RT
Proface output module EXM-DRA16RT
Output points: 16 point relay a-connect