Motor series: medium inertia, medium capacity.
Using a serial absolute / incremental encoder.
Rated output power: 0.85kw.
Rated speed: 1000rpm.
With a brake band.
Shaft end: straight shaft.
The structure of the AC servo motor stator is basically similar to the capacitor split phase single-phase induction motor MITSUBISHI MR-J3-700BS4.
The stator is provided with two positions of 90 degrees of mutual difference of the winding, one is the excitation winding Rf, it is always connected to the AC voltage Uf;
The other is to control the winding L, which is connected to the control signal voltage Uc
MR-J3-700BS4
So the AC servo motor, also known as the two servo motor MITSUBISHI MR-J3-700BS4. Motor series: flat type, medium and small power.
Rated output power: 5 . 0kw.
Rated speed: 2000r/min.
Whether to take the brake: No.
Shaft end: Standard (straight).
Protection level: IP65 (IP67).
Features: flat type design makes this more suitable for installation in space.
Application examples: robot, food manufacturing machinery.
High resolution encoder 131072p/rev (17 bit).
The encoder with high resolution ensures excellent performance and stability at low speed MITSUBISHI MR-J3-700BS4.
All motor dimensions are the same as before and all are compatible with the wiring. Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/1 public end.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
20 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoidd valve can be knnown,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 outtput, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MR-J3-700BS4 MR-J3-700BS4.
MR-J3-700BS4 Operation manual/Instructions/Model selection sample download link: