Protocol: SLMP, TCP/IP, UDP.
Communication mode: full duplex / half duplex.
At the same time can open a few: 4 connection.
Weight: 0.3kg.
Connect PLC FX3U/FX3UC to Ethernet.
Support fixed buffer storage, communication connection MELSOFT, through the MC communication protocol, e-mail messages.
When connected to the MELSOFT, through the Works2 PLC can achieve the remote maintenance of GX program MITSUBISHI MR-J3-10BS.
Connecting FX3UC, FX3GC requires FX2NC-CNV-IF or FX3UC-IPS-5V
MR-J3-10BS MITSUBISHI general purpose AC servo amplifier MELSERVO-J2-Super series.
Rated output: 22.0kw.
SSCNET interface.
Voltage: 3 phase AC200VAC or single phase AC230V.
Complete synchronization system with SSCNET high speed serial communication,
The communication cycle between the controller and the servo amplifier is the longest 0 MITSUBISHI MR-J3-10BS. 888ms.
Such systems will be able to provide high reliability and high performance.
When connecting the servo system with SSCNET,
In the motion system, the parameters of the servo amplifier and the acquisition of the data will be displayed on the motion controller MITSUBISHI MR-J3-10BS.
Connect a dedicated cable with an amplifier and a controller to form a SSCNET system .
This simple connection method reduces the routing time and helps to prevent noise.
Even in the MELSERVO-J2-SUPER series products using high resolution coding standards, the command frequency is no limit.
It is only necessary to add a battery on the servo amplifier, which can form the absolute value system.
Currently there are more than 1000000 high reliability SSCNET servo amplifier networks in use.CPU connection program input device.
ACPU use. Convert connectors to e-CON.Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DDC24V/0 .5A.
Exxternal connection: 3 line /2 line type MR-J3-10BS.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
TThe human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool MR-J3-10BS.
MR-J3-10BS Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-J3-10BS&select=5