"MITSUBISHI general purpose AC servo amplifier MELSERVO-J2-Super series.
Rated output: 5.0kw.
SSCNET interface.
Voltage: 3 phase AC200VAC or single phase AC230V.
Complete synchronization system with SSCNET high speed serial communication,
The communication cycle between the controller and the servo amplifier is the longest 0 MITSUBISHI MR-H200TN. 888ms.
Such systems will be able to provide high reliability and high performance
MR-H200TN
When connecting the servo system with SSCNET,
In the motion system, the parameters of the servo amplifier and the acquisition of the data will be displayed on the motion controller.
Connect a dedicated cable with an amplifier and a controller to form a SSCNET system MITSUBISHI MR-H200TN.
This simple connection method reduces the routing time and helps to prevent noise .
Even in the MELSERVO-J2-SUPER series products using high resolution coding standards, the command frequency is no limit.
It is only necessary to add a battery on the servo amplifier, which can form the absolute value system.
Currently there are more than 1000000 high reliability SSCNET servo amplifier networks in use MITSUBISHI MR-H200TN. "Number of channels: 4 channels
Sensing method and temperature range: PT100
A1S64TC series component is a kind of temperature controller combined with ANS series CPU .
Components with temperature measurement input and built-in PID algorithm control output,
Can be used in a variety of temperature control occasions.
Each component controls up to 4 loops at most.
Thermocouple input or PT100 3 wire temperature sensor input.
Control output switching signal for the output of the transistor.
BW is a signal with broken line detection function. Multiple CPU units for A3VTS multiplex system.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage MR-H200TN.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnnected from the load MR-H200TN.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.