LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
MITSUBISHI R16PCPU R16PCPU
MITSUBISHI R16PCPU
For FXCPU direct connection.Axis of control: 8.
Operation cycle: 0.444ms, 0.888ms, 1.777ms, 3.555ms.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Boot time (operation cycle 0.444ms, 1 axes): 0.7ms.
Servo amplifier connection mode: SSCNET III /H.
Inter station distance (max): 100m MITSUBISHI R16PCPU.
External wiring connection: 40 pin connector two.
Straight line interpolation: 2 axis, 3 axis, 4 axis R16PCPU
Arc interpolation: 2 axes.
And the positioning module is the same, simple movement module can be set up simple parameters and through the control program to start,
Easy positioning control, advanced synchronous control, cam control, speed / torque control, and other motion control MITSUBISHI R16PCPU.
According to the user''s control requirements, from the maximum number of control axis to 2 axis, 4 axis, 8 axis, 16 axis type in the choice of the most suitable module .
Positioning control (sealant / adhesive coating equipment etc.).
Synchronous control / electronic cam control (pick and place machine, packing machine, etc.).
Speed / torque control (stamping machine, die casting machine, etc MITSUBISHI R16PCPU. ).
Speed / position control switching (production of semiconductor chips, etc . ).
IQ-R MELSEC series of simple movement module, positioning module, high-speed counter module for intelligent function module,
High speed and high precision motion control, position control and position detection can be carried out by simple programming.
The simple motion module has the same operation convenience as the positioning module,
Like motion controller for synchronous control, cam control and other advanced control.
Can be connected to the servo system dedicated to support high-speed synchronous network /H III SSCNET servo amplifier.
Motion control by simple programming.
Can be realized through the software gear, shaft, transmission, cam action.
The most suitable for milling spiral line interpolation.
Normal start, high speed start, multi axis simultaneous start.
High precision ON/OFF pulse time measurement. Pulse input: DC input.
Default input: DC input.
Count range: 0~167777215 .
Numbeer of stations: 4 stops R16PCPU.
Station type: remote equipment station.
Configuration of master / local station,
In addition to the other site network with different CC-Link in addition to the main station and the remote station configuration caan also be the main station and the local station configuration R16PCPU.
A local PLC can communicate with the master station PLC and other remote workstations.
R16PCPU Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=R16PCPU&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
With Ethernet CPU
Q100UDEHCPU
MITSUBISHI With Ethernet CPU Q100UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
CPU unit
Q3ACPU
MITSUBISHI CPU unit Q3ACPU
Input and output points: 2048 points. In
MITSUBISHI
CPU unit
Q2ASCPU
MITSUBISHI CPU unit Q2ASCPU
Input and output points: 512 points. Inp
MITSUBISHI
General purpose CPU
Q20UDHCPU
MITSUBISHI General purpose CPU Q20UDHCPU
Specification model: Q20UDHCPU. Input /