MITSUBISHI QS90SR2SP-EX QS90SR2SP-EX
MITSUBISHI QS90SR2SP-EX
2 slots.
Can be installed in the power supply unit for A series units installed QnA/.
Cannot extend.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage MITSUBISHI QS90SR2SP-EX.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load QS90SR2SP-EX
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action MITSUBISHI QS90SR2SP-EX.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point MITSUBISHI QS90SR2SP-EX.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 1.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase motor? Can single phaase power supply be used?
Basically can not be used QS90SR2SP-EX. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor exxplosion will be induced QS90SR2SP-EX.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.
QS90SR2SP-EX Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=QS90SR2SP-EX&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Safety relay module
QS90SR2SP-CC
MITSUBISHI Safety relay module QS90SR2SP-CC
Meet safety standards: EN954-1 class 4,
MITSUBISHI
Safety relay module
QS90SR2SN-Q
MITSUBISHI Safety relay module QS90SR2SN-Q
Application: Q series. Suitale for safe
MITSUBISHI
Safety relay module
QS90SR2SP-EX
MITSUBISHI Safety relay module QS90SR2SP-EX
Application: extension. Suitale for saf
MITSUBISHI
Safety relay module
QS90SR2SN-CC
MITSUBISHI Safety relay module QS90SR2SN-CC
Meet safety standards: EN954-1 class 4,