Input / output mode: transistor output (drain).
Output points: 16 points.
DC5V internal consumption current: 100mA.
DC24V internal consumption current: 125mA.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256 MITSUBISHI GT1030-LBLW.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points
GT1030-LBLW Master station module supporting AnyWireASLINK system.
Connecting sensor and programmable controller.
Free configuration of sensors, control of 512 points of the input and output MITSUBISHI GT1030-LBLW.
The AnyWireASLINK transmission line (2 lines) can be used for communication to supply power for the sensor, and the sensor can also be conveniently added .
Can through the project software GXWorks2 batch management sensor shedding detection and from the station module settings, etc.,
Substantial savings in time and cost.Servo motor series: low inertia, medium / high power MITSUBISHI GT1030-LBLW.
Rated output: 37.0kw.
Rated speed: 1500r/min.
Electromagnetic brake: No .
Shaft end specification: Standard (straight axis).
Features: low inertia has low medium and high speed three models, suitable for different applications as a standard, 30KW and above servo motor can be installed flange or bracket.
IP level: IP44.
Application example:
1, injection molding machine.
2, semiconductor manufacturing equipment.
3, large material handling system.
4, stamping machine.
Abundant motor product line can optimize the performance of the machine.
Has a rich motor product line including a rotary servo motor, linear servo motor and direct drive motor. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 30KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, evven if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection) GT1030-LBLW.
If the given acceleration time is too short, the output frequency of the inverter is far more than thhe change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall GT1030-LBLW.
GT1030-LBLW Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=GT1030-LBLW&select=5