LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
AJ35T-M12B-K MITSUBISHI AJ35T-M12B-K
MITSUBISHI AJ35T-M12B-K
"Universal output function: source type.
Program capacity: 20K step.
Basic operations processing speed: 60ns.
Communication interface: USB/RS-232.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
Unable to install display module (L6DSPU-C-CM), RS-232 adapter, RS-422/485 adapter MITSUBISHI AJ35T-M12B-K.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool AJ35T-M12B-K
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement MITSUBISHI AJ35T-M12B-K.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s MITSUBISHI AJ35T-M12B-K.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators . "DC input points: 32 points.
Input voltage and current: 3/7mA, DC12/24V.
Response time: 10ms.
Positive pole sharing.
Output points: 16 points.
Output voltage and current: 100mA/1, DC12/24V point.
Response time: 2ms.
48 point /1 public side (input and output sharing).
Output form: transistor output, leakage type.
40 pin connector.
Number of stations: 1 stops.
Type remote I/O unit (twisted pair data connection).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a haard wired way, annd the timeliness is strong AJ35T-M12B-K.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too gguarantee the timeliness AJ35T-M12B-K.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
AJ35T-M12B-K Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=AJ35T-M12B-K&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Analog module
AJ35T-M04B-R
MITSUBISHI Analog module AJ35T-M04B-R
Analog channel: 4 channels. Input / outp
MITSUBISHI
Analog module
AJ35T-M12B-R
MITSUBISHI Analog module AJ35T-M12B-R
Analog channel: 12 channels. Input / out
MITSUBISHI
Analog module
AJ35T-M16B-K
MITSUBISHI Analog module AJ35T-M16B-K
Analog channel: 16 channels. Input / out
MITSUBISHI
Analog module
AJ35T-M16B-R
MITSUBISHI Analog module AJ35T-M16B-R
Analog channel: 16 channels. Input / out