Control axis: maximum 4 axes.
Operation cycle: 0.88ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points.
Color detecting set: 4 set.
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and torque (push pressure control) and other advanced motion control MITSUBISHI A70BDE-J71QBR13.
Equipped with standard synchronous encoder and color detection function necessary function A70BDE-J71QBR13
Can be no procedures for setting. Strong support for MELSOFT.
Can fully apply LD77MH of the old program.
Let motion control more simple. Input points: 32 points.
Voltage: AC100 ~ 120V MITSUBISHI A70BDE-J71QBR13.
Current: 12mA.
Response time: 25ms.
32 points / a common end.
38 point terminal station .
CE certification.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear MITSUBISHI A70BDE-J71QBR13.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive .
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The coontents of the compoonent image register are changed with the change of the execution of the program A70BDE-J71QBR13.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to thhe adoption of centralized sampling A70BDE-J71QBR13.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
A70BDE-J71QBR13 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=A70BDE-J71QBR13&select=5