Actuator: Fork lever lock (right operation).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/2NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available D4C-6301. )
M12-connector models are also available, saving on labor and,
simplifying replacement
D4C-6301
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4C-6301.
Certified standards: UL, EN (TÜV), and CCC. Output: SPDT.
Lighting: LED without Voltage Reduction Unit .
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry D4C-6301.
Detachable Switch.
The same contacts can be used for both standard loads and microloads .
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Appearance: Flat Unshielded.
Sensing distance: 10 mm[4 to 10 mm *].
Output configuration: DC 3-wire NPN.
Model/Operation mode: NO.
Flat Capacitive Sensor with a.
Thickness of Only 10 mm.
Flat Sensor with excellent space efficiency.
(Model with built-in Amplifier is only 10 mm thick.)
Direct mounting onto a metallic surface is possible. Application: General applications for purified water,
For 3-pole electrode (2-wire).
Separate Electrode Holders for Water.
Supply and Drainage Control in Buildings.
Small, Lightweight Electrode Holders for,
Use as Built-in Components.
The PS-@S(R) are separate Electrode Holders that allow the,
Electrodes to be withdrawn easily for inspection.
The PS-@S(R) come in 3, 4, or 5 pole models for supply and,
drainage of tap water in buildings.
PS-31 is a small and light-weight Electrode Holder that is,
suitable for installation in limited space and built-in components. Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
AC 380, 400, 415, 480, AC 220, 230, 240, 277.
Ideal for 3-phase voltage asymmetry.
monitoring for industrial faacilities and equippment OMRON D4C-6301.
Monitor voltage asymmetry, phase sequence, and phase loss,
for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
One SPDT output relay, 6 AA aat 250 VAC (resistive load) OMRON D4C-6301.
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator.
D4C-6301 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4C-6301&select=5