Output: SPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 100/110 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia D4C-1210. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch
D4C-1210
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Size: M12 (Brass); Single; Unshielded.
Sensing distance: 10 mm.
Connecting method (See note 1 D4C-1210. ): M12 Connector.
Body length: Long.
Output configuration: PNP .
Operation mode NC.
A new generation in global applications. Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.063 A; 60 Hz, 0.055 A .
Rated input: 50 Hz, 5 W ; 60 Hz, 4 W .
Rated rotational speed: 50 Hz, 1900 r/min; 60 Hz, 2100 r/min D4C-1210.
Maximum flow rate: 50 Hz, 0.4 m3/min; 60 Hz, 0.5 m3/min.
Maximum static pressure: 50 Hz, 19 . 5 Pa; 60 Hz, 23.5 Pa.
Noise: 50 Hz, 28 dB; 60 Hz, 30 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, connvenient to check tthe state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV OMRON D4C-1210.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput OMRON D4C-1210.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
D4C-1210 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D4C-1210&select=5