LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
OMRON B500-OF411 B500-OF411
No PHOTO
next one: OMRON B500-OF311
Last one: OMRON B500-OF501
OMRON B500-OF411
Output: SPDT.
Lighting: LED.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry OMRON B500-OF411.
Detachable Switch.
The same contacts can be used for both standard loads and microloads B500-OF411
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2 OMRON B500-OF411.
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) *2 .
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, None .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel OMRON B500-OF411.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices .
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used foor independent heating/cooling PID control B500-OF411.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit. C500-AS Speciaal I/O Unit ASCII BASIC UNIT C500-ASC01 B500-OF411. CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP217-E.
8-MB memory; w/o floating-point processor.
B500-OF411 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=B500-OF411&select=5


...more relevant model market price >>>>