OMRON A3SA-90B1-05ER A3SA-90B1-05ER
OMRON A3SA-90B1-05ER
Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, DPST-NO/DPST-NC; Auxiliary Contact Block, SPST-NO/SPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations) OMRON A3SA-90B1-05ER.
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations) A3SA-90B1-05ER
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections OMRON A3SA-90B1-05ER.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block .
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels OMRON A3SA-90B1-05ER.
According to OMRON investigation of IIEC-AC1 50 A specifications . Number of beams: 64.
Protective height: 1280mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Size: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance perfformance .
The connnection method can be selected from a screw terminal and a PUSH-IN fastening terminal A3SA-90B1-05ER.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsiion Village (sold separately) connected to the computer after,
No power connection can be set A3SA-90B1-05ER.
It can be easily set by CS-Thermo (sold separately).
A3SA-90B1-05ER Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=A3SA-90B1-05ER&select=5


...more relevant model market price >>>>
Related products
OMRON
Lighted Pushbutton Switch
A3SA-90B1-12EG
OMRON Lighted Pushbutton Switch A3SA-90B1-12EG
Contact type: Standard load 250 VAC, 2
OMRON
Lighted Pushbutton Switch
A3SA-90D1-28A
OMRON Lighted Pushbutton Switch A3SA-90D1-28A
Contact type: Standard load 250 VAC, 2
OMRON
Lighted Pushbutton Switch
A3SA-90B1-05ER
OMRON Lighted Pushbutton Switch A3SA-90B1-05ER
Contact type: Standard load 250 VAC, 2
OMRON
Lighted Pushbutton Switch
A3SA-90C1-06W
OMRON Lighted Pushbutton Switch A3SA-90C1-06W
Contact type: Standard load 250 VAC, 2