Mounted Connector: MR Sockets.
No. of poles: 50.
Dimension A: 184.
Dimension B: 144.
Mounted Connector model: MR-50RFD2 *3.
Cable Connector model: MR-50M *3.
New Slim Connector-Terminal Block,
Conversion Units.
Mounting area reduced by 35% (in comparison with,
40-pole XW2B Units) to contribute to downsizing,
control panels and automatic equipment A22RL-FA-6A-20M Price.
Fallout prevention for terminal screws
A22RL-FA-6A-20M
Round or forked crimp terminals can be used.
Mount to DIN Track or via screws.
Unique DIN Track lock can maintain open status,
during DIN Track attachment and removal.
Terminal cover can be locked open.
Screw terminals are arranged by color in groups,
of five to simplify counting terminal numbers A22RL-FA-6A-20M Price. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function A22RL-FA-6A-20M Price.
Event entry point: 2.
Transfer output: transfer output (special terminal) .
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including OON/OFF control, phase conttrol, and cyclic control OMRON A22RL-FA-6A-20M.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreentt relay or for motor or lamp loads OMRON A22RL-FA-6A-20M.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
A22RL-FA-6A-20M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22RL-FA-6A-20M&select=5