Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified
A22L-CG-T1-02M
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend OMRON A22L-CG-T1-02M.
External event input can be applied to a variety of measurementCable core number: 4 .
Cable lead direction: straight line type.
Cable length: 5m.
Save time, save maintenance cost,
With a waterproof connector environment and strong tolerance of FA.
For IP67, the FA 94V-0 connector small special flammability.
The wiring system makes the device more maintainable connector,
And reduce the downtime of equipment OMRON A22L-CG-T1-02M.
Introduction of connector and modular connector with cable.
A modular connector crimping type, welding type, screw connection type 3 .
With the cable connector is obtained UL certification of products.
According to IEC61076-2-101 (IEC60947-5-2), NECA4202. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer .4.3 CX-Thermo)) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output A22L-CG-T1-02M.
Through the infrared port can be carried out from the frronnt of the communication A22L-CG-T1-02M.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
A22L-CG-T1-02M Operation manual/Instructions/Model selection sample download link: