Sensing method: Retro-reflective with MSR function.
Connection method: Pre-wired (2 m).
Sensing distance: 3 m (150 mm).
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models OMRON A165L-JWA-12D-2.
Mechanical axis and optical axis offset of less than ±2
A165L-JWA-12D-25° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Supply voltage: 100 to 240 V AC, 50/60 Hz (wide range) OMRON A165L-JWA-12D-2.
Operating voltage range: 85 to 265 V AC.
Output capacity: 5 V DC: 3.6 A(18 W).Name: Sensing Band Stickers .
Remarks: 30 Stickers per set.
SUS316 used for core and polyethylene used for sheath to en,
sure high resistance to both acidic and alkaline liquids.
Sensing Band Stickers that use the same material as the Sens,
ing Band’s insulating resin are available in 2 types: adhesive,
tape type and screw type OMRON A165L-JWA-12D-2. Cable specifications: Oil-resistant Polyurethane Cable.
Cable length L: 2 m .
Cable outer diameter: 6 mm.
Straight Connectors.
Minimum order: 5.
UL: --.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UUL Class 2 Output sttandards A165L-JWA-12D-2.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) A165L-JWA-12D-2.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
A165L-JWA-12D-2 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A165L-JWA-12D-2&select=5