Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA; 1/4,00.
Conversion period: 1 ms/point.
Accuracy at ambient temperature of 25°C:
Voltage: ±0 OMRON . 3% of F.S. Current: ±0.5% of F.S.
External connection: Removable terminal block
CJ1W-TC102
External power supply: 24 VDC +10% -15%, 200mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 24V, 0.2*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup OMRON .
Analog Input Units for converting analog input,
signals into binary data .
Analog Output Units for converting binary ,
data into analog output signals.
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver) OMRON .
Control mode: standard or heating cooling.
Auxiliary output points: 3 points .
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. CV500-CN Cable Motion Control Connecting Cables 2 m CV500-CN224Power supply voltage: 24V DC±10%, Ripple (p-p): 10%.
Current consumption: 0.9A max.
Discharge voltage: ±7.5kV.
Discharge method: Variable DC.
Ionization time: 1.5 s.
Ion balance: ±10V max.
Amount of ozone generated: 0.01 ppm,
(Measured at a distance of 50 mm from air outlet).
Indicators: Power (Green), Fan running (Green), Cleaning (Yellow), Alarm (Red).
Main functions: Ion balance adjustment (Automatic and manual).
External output (for both cleaning and alarm outputs): Photo MOS relay output,
(NPN or PNP)Applied voltage: 30VDC max., load current: 100mA max.
Residual voltage: 1V max.
Discharge stop input: No-voltage contact input, ON: 0V short circuit,
OFF: Open (leakage current: 0.1mA max.).
Ambient temperature range: 0 to 50˚C (No icing or dewing).
Ambient humidity range: 35% tto 65% (No icing or ddewing) OMRON CJ1W-TC102.
Weight (Packaged): Approx. 0.6 kg (Approx. 1.2 kg).
Material: Body:Aluminum, ABS Electrode needle: Tungsten.
Accessories: Instruction sheet, I/O connector, L-mounting bracket, Streamer.
This ionizer series is designnedd to go anywhere OMRON CJ1W-TC102.
All models are easily installed on narrow,
workbenches or in high positions where earlier,
models presented installation issues.
CJ1W-TC102 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=CJ1W-TC102&select=5