Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 1500W.
Output voltage: 24V.
Output current: 65A (AC100V) 70A (AC200V) peak current 105A (AC200V).
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device OMRON .
Built in support for determining the abnormal causes of the new under voltage detection function
A22L-DG-T2-10M
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products OMRON .
Meet RoHS instructions including lead free .
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer OMRON . )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
Terminal (Wire connection): Screw terminal.
Classification: Standard.
Latching lever (Test switch): Yes.
Rated input voltage: DC, 24V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet tthe screw type needs .
MMounted relay uses plug-in terminals that are difficult to,
bend when exchanging OMRON A22L-DG-T2-10M. Terminal: Screw terminal (-B).
Actuator: Short hinge lever.
Direct Current Switch with.
Built-in Magnetic Blowout.
Incorporates a small peermmanent magnet in the contact OMRON A22L-DG-T2-10M.
mechanism to deflect the arc to effectively extinguish it.
Same shape and mounting procedures as the Z Basic Switches.
A22L-DG-T2-10M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22L-DG-T2-10M&select=5