A small, high resolution general type of hollow shaft with no need for coupling.
Incremental diameter (38 hollow shaft).
With 8 shaft hole.
Corresponding supply voltage DC5 ~ 24V (open collector output type).
Outer diameter of 38, with high resolution 3600P/R.
Power supply voltage: DC5 ~ 24V.
Output form: open collector output (NPN output) OMRON D2A-2110.
Output: DPDT.
Lighting: LED without Voltage Reduction Unit
D2A-2110
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia OMRON D2A-2110. Body.
Miniature design of 28.5 mm, the smallest class in the industry .
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Cable length L: A, 15.0 m; B, 14.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch OMRON D2A-2110. I/O capacity/Mountable Units(Expansion Racks): 2, 560 points/40 Units (3 Expansion Racks max . ).
Program capacity: 120K steps.
CJ1H-CPU66H Data memory capacity: 256K words(DM: 32K words, EM: 32K words × 7 bank).
LD instructioE5@C Series That Pursues Greater Visibility with Large White PV Display.
Models with Push-In Plus Terminal Blocks That Reduce Wiring Work,
DIN Track-mounting Models That Are Ideal for Connecting to PLCs,
Plug-in Models That Are Convenient for Maintenance,
and Programmable Models for a Wider Range of Application.
A Wide Lineup of Models to Meet a Wide Range of User Needs. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is inndicated from the start of operation D2A-2110.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions D2A-2110. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.