Classification: Micro load.
Contact gap: H (0.25 mm).
Actuator: Panel mount plunger; Medium OP.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types OMRON CPM2C-10CDT1M-D.
A series of standard models for micro loads is available
CPM2C-10CDT1M-D
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity OMRON CPM2C-10CDT1M-D.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting) .
included in lineup. Case color: Light gray.
Lighting method: LED; 24 VDC.
Display color symbol: R.O.G.W.
Large Rectangular-bodied Indicators.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting),
included in lineup OMRON CPM2C-10CDT1M-D. Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 16 outputs(High speed);
Maximum switching capacity, 24VDC, 0 . 5A;
Commons, 16 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.15A; 24V, --.
Standards: N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA.
Resolution: 1/4,000 (Settable to 1/8,000).
Conversion period: 1 ms/point,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
Exteernal power supply: 24 VDC +10% -15%, 140mA max CPM2C-10CDT1M-D.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaaloog Input Units for converting analog input,
signals into binary data CPM2C-10CDT1M-D.
Analog Output Units for converting binary ,
data into analog output signals.
CPM2C-10CDT1M-D Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=CPM2C-10CDT1M-D&select=5