Classification: Thermistors.
Temperature range (See note 3.): -50°C to 300°C.
Element type: Thermistor.
Conductor type: Elementinterchangeable thermistor.
Class: 1.
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 31.
A Wide Variety of High-precision.
Temperature Sensors OMRON A3CT-90A0-W.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work
A3CT-90A0-W
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON A3CT-90A0-W. Cable Specifications: Fire-retardant, Robot cable .
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 3.
Cable core cross sectional area: 0.5 mm.
Cable length: 1 m.
DC.
Minimum order: 10.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating OMRON A3CT-90A0-W.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Type: 1a1b welding terminal.
Shape: rectangle.
Type: General load.
Action: instantaneous action (auto recovery).
With light: LED with light.
Using voltage: DC12V.
Operation Department color: white.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. Measuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resettingg and automaticaally resetting supported by one Relay A3CT-90A0-W.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input ssuppported A3CT-90A0-W.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
A3CT-90A0-W Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A3CT-90A0-W&select=5