Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element OMRON A22TK-2LL-21-K01.
Burnout Detector compatible with a,
wide-range of heater control methods
A22TK-2LL-21-K01
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control OMRON A22TK-2LL-21-K01.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance .
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Measuring current: 10 to 100 A AC, 20 to 200 A (See note OMRON A22TK-2LL-21-K01. ).
Supply voltage: 200-230 VAC.
Ideal for current monitoring for,
industrial facilities and equipment .
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Operating method: Incrementing, decrementing, and reversible (UP/DOWN A to F).
Mounting method: Flush mounting.
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Memory backup: No.
Display: Yes (8-mm high 7-segment LED).
Models: 6 digits.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed roller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulatiing material .
Cablee lengths of 3 and 5 m available on standard models A22TK-2LL-21-K01.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfiirmation of operation A22TK-2LL-21-K01.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
A22TK-2LL-21-K01 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22TK-2LL-21-K01&select=5