Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/RJ45).
Cable length: 5 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V) OMRON A22R-TR-02A.
Shell color: black.
Control output: relay output.
Control mode: standard.
Auxiliary output points: -
A22R-TR-02A
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade OMRON A22R-TR-02A.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement .
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay OMRON A22R-TR-02A. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 50cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance funcction is increassed,
Further performance improvement A22R-TR-02A.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV A22R-TR-02A.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
A22R-TR-02A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22R-TR-02A&select=5