Appearance: Standard.
Sensing method: Through-beam type (with slot).
Cable length: 2 m.
Sensing distance: 5 mm (slot width).
configuration Output: Light-ON.
Indicator mode: Incident light.
Model: NPN output.
Slim, Compact Photomicrosensor.
that is still easy to use.
Compact, thin profile enables dense mounting OMRON A22L-DA-24A-11M.
Indicator is visible from both sides.
Wide operating voltage range: 5 to 24 VDC
A22L-DA-24A-11M Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general) OMRON A22L-DA-24A-11M.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input .
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use OMRON A22L-DA-24A-11M.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm .
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Water Leak Alarm.
Flexible Setup according to Water Quality,
and Surrounding Wiring Conditions.
The operating resistance has a variable sensiitivity from 0 to,
50 kΩ, so the best set values can be made according to the pre,
dicted water leakage, degree of overflow, water quality, or sur,
rounding wiring conditions A22L-DA-24A-11M.
The power supplied to the Sensing Band is 24 VAC, so opera,
tion iss sstable because there is no electrode deterioration from,
electrical corrosion A22L-DA-24A-11M.
A contact signal output enables monitoring from remote loca,
tions.
A22L-DA-24A-11M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22L-DA-24A-11M&select=5