A22L-CW-T1-10M OMRON A22L-CW-T1-10M
OMRON A22L-CW-T1-10M
Sensor method: Throughbeam.
Case material: Brass.
material Sheath: --.
Connection method: M12 connector.
Sensing distance: 10 m.
Output: PNP.
Detects Intrusions into Hazardous.
Areas with a Single Beam and.
Complies with International Safety.
Standards. Operation indicator: With operating indication; Standard load OMRON A22L-CW-T1-10M.
Ratings: 4 A at 30 VDC.
Actuator: Adjustable rod lever.
Cable length : 3m A22L-CW-T1-10M
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection OMRON A22L-CW-T1-10M.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material .
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers OMRON A22L-CW-T1-10M.
Models with red LED indicators added to series for easy,
confirmation of operation .
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including OON/OFF control, phaase control, and cyclic control A22L-CW-T1-10M.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreentt relay or for motor or lamp loads A22L-CW-T1-10M.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
A22L-CW-T1-10M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=A22L-CW-T1-10M&select=5


...more relevant model market price >>>>
Related products
OMRON
Pushbutton Switch
A22L-HA-T1-10M
OMRON Pushbutton Switch A22L-HA-T1-10M
Appearance: Round/Half-guard type LED vo
OMRON
Pushbutton Switch
A22L-CW-T2-10A
OMRON Pushbutton Switch A22L-CW-T2-10A
Appearance: Square/Projection type LED v
OMRON
Pushbutton Switch
A22L-GW-T1-10M
OMRON Pushbutton Switch A22L-GW-T1-10M
Appearance: Round/Full-guard type LED vo
OMRON
Pushbutton Switch
A22L-CW-T2-01A
OMRON Pushbutton Switch A22L-CW-T2-01A
Appearance: Square/Projection type LED v