Size: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V) OMRON A22-DR-02A.
Shell color: black.
Control output: voltage output (SSR driver)
A22-DR-02A
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: - OMRON A22-DR-02A.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved .
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors OMRON A22-DR-02A.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Cable length L: 10.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: -.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, suupport for a vaariety of applications A22-DR-02A.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) A22-DR-02A.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
A22-DR-02A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22-DR-02A&select=5