Power supply voltage: DC100V.
Note: operation with output contacts.
Power supply unit.
The power supply of the CPU rack is supplied by the power supply unit.
The following power units are available for selection.
C200HW-PA204 (voltage: AC100-120V/AC200-240V)
C200HW-PA204S (voltage: AC100-120V/AC200-240V)
C200HW-PA204R (voltage: AC100-120V/AC200-240V)
C200HW-PD024 (voltage: DC24V)
In the past, PC connected to a measurement equipment or components must be given to the ASCII unit or BASIC unit to write a communication program
MSF4800-IP67-1880
Now, PC C200HX/HG/HE is installed on the communication protocol macro function,
Can be configured to these communications procedures through the PMCR instruction to the ladder program,
With this function system can be easily connected with a wide range of components MSF4800-IP67-1880. Isolation: Phototriac Coupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 20 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State MSF4800-IP67-1880.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series .
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Appearance: Round/Full-guard type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-G.
Output: SPST-NC.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the SSwitch Unit OMRON MSF4800-IP67-1880.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounteed using either open-type (fork-type) or closed-type OMRON MSF4800-IP67-1880.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
MSF4800-IP67-1880 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MSF4800-IP67-1880&select=5