Size: K8AB-TH 22.5 × 90 × 100 mm.
Supply voltage: 100 to 240 VAC.
Type: Temperature input.
Number of outputs: 1 (relay).
Input type: Thermocouple.
Setting unit (setting range): Unit: 10°C/°F (See note 1.).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored MK3P-2 AC50.
Temperature monitoring in slim design with a width of just 22
MK3P-2 AC505 mm.
Simple function settings using DIP switch.
Universal-input support for thermocouple or Pt100 sensor input.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator MK3P-2 AC50. Model: CPM2C-MAD11. 2 analog inputs and 1 analog outputTerminal: Solder terminal (-1A) .
Actuator: Hinge roller lever; High OT.
DPDT Basic Switch for Two.
Independent Circuit Control.
Ideal for switching the circuits operating on two,
different voltages, and for controlling two independent circuits.
Interchangeable with OMRON Z Basic Switches,
as both switches are identical in mounting hole,
dimensions, mounting pitch and pin plunger position MK3P-2 AC50. Output: DPDT.
Lighting: Incandescent lamp.
Operating voltage: 5 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated ffrom the start of operation OMRON MK3P-2 AC50.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions OMRON MK3P-2 AC50. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
MK3P-2 AC50 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MK3P-2 AC50&select=5