OMRON M16-JW-5D
Type: output module.
Insulation mode: three end two-way photoelectric switch.
Action indicator: there.
Zero trigger function: No.
Applicable load of output: AC100 2A ~ 240V.
Input rated voltage: DC12V.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete M16-JW-5D.
Can be used for I/O type P7TF terminal. Can also be mixed with the I/O type G7T relay M16-JW-5D
Can check the working status of SSR through the action indicator.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)Rated voltage: 115 V M16-JW-5D.
Permitted voltage fluctuation range: 85% to 110% rated voltage .
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.200 A; 60 Hz, 0.180 A.
Rated input: 50 Hz, 15 W ; 60 Hz, 14 W .
Rated rotational speed: 50 Hz, 2,750 r/min; 60 Hz, 3200 r/min.
Maximum flow rate: 50 Hz, 2.7 m3/min; 60 Hz, 3.1 m3/min.
Maximum static pressure: 50 Hz, 93.1 Pa; 60 Hz, 99.0 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 46 dB M16-JW-5D.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment .
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Control power supply voltage: 100/110 VAC.
Input: DC, Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using currennt converter .
Avaiilable in 7 supply voltage configurations OMRON M16-JW-5D.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrsee current detection OMRON M16-JW-5D.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
M16-JW-5D Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=M16-JW-5D&select=5


...more relevant model market price >>>>
Related products
OMRON
Indicator
M16-TW-5
OMRON Indicator M16-TW-5
Appearance: Rectangular M16-T. Lighti
OMRON
Indicator
M16-AG-12D
OMRON Indicator M16-AG-12D
Appearance: Rectangular M16-A. Lighti
OMRON
Indicator
M16-AA-5D
OMRON Indicator M16-AA-5D
Appearance: Rectangular M16-A. Lighti
OMRON
Indicator
M16-JY-5D
OMRON Indicator M16-JY-5D
Appearance: Rectangular M16-J. Lighti