Sale K3NH-TA2A-FLK1 OMRON K3NH-TA2A-FLK1
No PHOTO
OMRON K3NH-TA2A-FLK1
Type: Shielded.
Appearance: Flat, 30 × 14 × 4.8 mm.
Sensing distance: 5 mm.
Repeat accuracy: 2 μm.
Cable specification: With Protective Spiral Tube.
Proximity Sensor with Separate.
Amplifier Enables Easily Making High.
precision Sensitivity Settings.
Wide variety of Sensor Heads to select according to the,
application K3NH-TA2A-FLK1. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads K3NH-TA2A-FLK1
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function K3NH-TA2A-FLK1.
Check the sensing excess gain level on the digital display .
Support for high-precision positioning and screening with,
fine positioning to maximize variations.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit. Cable length L: 1.5 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch K3NH-TA2A-FLK1. Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function) .
Operating voltage: 200/220 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer .4.3 CX-Thermo) makess the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output OMRON K3NH-TA2A-FLK1.
Through the infrared port can be carried out from the frronnt of the communication OMRON K3NH-TA2A-FLK1.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
K3NH-TA2A-FLK1 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=K3NH-TA2A-FLK1&select=5


...more relevant model market price >>>>