Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element K2CU-F10A-DGS.
Burnout Detector compatible with a,
wide-range of heater control methods K2CU-F10A-DGS
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K2CU-F10A-DGS.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance .
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). High performance price ratio standard type proximity sensor K2CU-F10A-DGS.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor .
Type: DC three wire / wire type.
Shape: shield, M8.
Detection range: 1.5mm.
Output configuration: NPN.
Action mode: NC. Terminal: Solder terminal.
Actuator: Reverse hinge lever.
Direct Current Switch with.
Built-in Magnetic Blowout.
Incorporates a small permanent magnet in the contact.
mechanism to deflect the arc to effectively extinguish it.
Same shape and mounting procedures as the Z Basic Switches. Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.170 A; 60 Hz, 0.150 A .
Rated input: 50 Hz, 11 W ; 60 Hz, 10 W .
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2250 r/min.
Maximum flow rate: 50 Hz, 2.0 m3/min; 60 Hz, 2.1 m3/min.
Maximum static pressure: 50 Hz, 44.1 Pa; 60 Hz, 44.1 Pa.
Noise: 50 Hz, 36 dB; 60 Hz, 38 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 ttype) and metal-bladed mmodels,
(28 type) included in series OMRON K2CU-F10A-DGS.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffieed safety standards depend on the,
product OMRON K2CU-F10A-DGS. Check the information given for available models of Axial fans and,
the information in Characteristics.
K2CU-F10A-DGS Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=K2CU-F10A-DGS&select=5


...more relevant model market price >>>>
Related products
OMRON
Heater Element Burnout Detector
K2CU-F20A-D
OMRON Heater Element Burnout Detector K2CU-F20A-D
Control supply voltage: 110 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F10A-C
OMRON Heater Element Burnout Detector K2CU-F10A-C
Control supply voltage: 100 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F80A-E
OMRON Heater Element Burnout Detector K2CU-F80A-E
Control supply voltage: 200 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU Series
OMRON Heater Element Burnout Detector K2CU Series
Accurate Detection of Heater Element. B