Output: SPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28 G70V-ZOM16P. 5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
G70V-ZOM16P
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Actuator: Roller lever (metal lever, bearing roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action) G70V-ZOM16P.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards .
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability G70V-ZOM16P.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) .
Certified standards: UL, EN (TÜV), and CCC. Sensing method: Through-beam.
Connection method: Pre-wired (2 m).
Sensing distance: 25 mm.
No. of opti- cal axes: 1.
Model: NPN output.
Photoelectric Sensor with Grooved.
Design and Easy Settings .
Groove-type Sensor with groove width of 25 mm.
Models are available with one or two light axes.
Models are available with M8 pre-wired connectors. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtheer performance improvement OMRON G70V-ZOM16P.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV OMRON G70V-ZOM16P.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
G70V-ZOM16P Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=G70V-ZOM16P&select=5