Shape: Cylindrical.
Dimensions: 8 dia. x 22 mm.
Sensing distance: 2 mm.
Resolution: 1 μm.
High-accuracy Detection of Metal Workpiece Displacement.
Sensor Heads support a wide variety of applications.
Linearity can be adjusted for non-ferrous metals,
such as SUS and aluminum, using the material selection function MM4XP-NC01 DC110 Price.
Simple linearity compensation (teaching).
Easily perform calculation for two Sensors by using a Calculating Unit
MM4XP-NC01 DC110
Prevent mutual interference for up to five Units by using a Calculating Unit. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) MM4XP-NC01 DC110 Price.
Shell color: black.
Control output: current output .
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / MM4XP-NC01 DC110 Price.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance .
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. E3F3-D66M detection method: diffuse reflection type,
Lead extraction: CN M12,
Type: metal appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyPower ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: --.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UUL Class 2 Output standardss OMRON MM4XP-NC01 DC110.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) OMRON MM4XP-NC01 DC110.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
MM4XP-NC01 DC110 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MM4XP-NC01 DC110&select=5