Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 3 points (common universal).
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485 OMRON MKS3PN-V-5 AC24.
Event input: 1 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility
MKS3PN-V-5 AC24
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility OMRON MKS3PN-V-5 AC24.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications .
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set OMRON MKS3PN-V-5 AC24.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication .
Combined temperature control device through component communication. Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display.
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DeviceType of drive rod: one-way action roller type (vertical motion).
Conduit size: single catheter type, M20.
Built in switcch structure: slow mmotion (2NC) MKS3PN-V-5 AC24.
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forcedd oopen action structure MKS3PN-V-5 AC24.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used.
MKS3PN-V-5 AC24 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MKS3PN-V-5 AC24&select=5