Number of beams: 20.
Protective height: 970mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions OMRON MK3P-2 AC100/110. Supply voltage: 100 to 240 VAC.
6-digit total counter/time counter: Black.
DIN 72 x 36-mm Total Counter/Time Counter with
MK3P-2 AC100/110
Easy-to-read Displays and Water and Oil.
Resistance Equivalent to IP66.
Large, easy-to-read displays: 15-mm-high characters for 6-digit mod,
els; 12-mm-high characters for 8-digit models OMRON MK3P-2 AC100/110.
High-visibility, negative transmissive LCD display with built-in red LED,
backlight at low power consumption .
IP66 with oil resistance and NEMA4 are achieved by unifying the front,
with the casing case and using oil-resistant materials and parts.
Compact (66 mm) body.
Switch 6-digit models between total counter and time counter operation,
Just change a switch setting for either an NPN or PNP input OMRON MK3P-2 AC100/110.
Supports both external resetting and manual resetting.
Finger-protection terminal block cover prevents electrical shock and,
conforms to VDE0106, Part 100 .
Safety standards: UL, CSA, EMC (EN 61326), CE Marking.
Cable specifications: Fire-retardant, Robot cable.
Cable length L: 5 m.
Cable outer diameter: 6 mm.
Straight Connectors.
Minimum order: 5.
UL: Yes.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: M12 connector.
Body material: Brass.
Thread length (overall length): 27 (43).
Ouutput configuration: PNP MK3P-2 AC100/110.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpiecees are eliminated MK3P-2 AC100/110.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization.
MK3P-2 AC100/110 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MK3P-2 AC100/110&select=5