Isolation: Phototriac.
Zero cross function: No.
Indicator: No.
Rated output load: 20 A at 100 to 240 VAC.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model H7AN-E2DM AC100-240 Price.
Dedicated, compact aluminum PCB and power elements used.
Built-in varistor effectively absorbs external surges
H7AN-E2DM AC100-240
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV) H7AN-E2DM AC100-240 Price. Size: 48 x 48mm.
Body: terminal type.
Type: control output 2 point type (power AC/DC24V) .
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: - H7AN-E2DM AC100-240 Price.
Transfer output: transfer output (special terminal).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products .
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultType: related equipment (sold separately); split type current transformer (CT).
Rated primary side current: 250A.
Rated two secondary current: 1A.
Simple monitoring of the use of electricity to support energy saving countermeasures.
On behalf of the use of the mechanical equipmennt, the measurement of the iniitial voltage, current,
Cumulative quantity, invalid power, power factor, frequency OMRON H7AN-E2DM AC100-240.
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, annd the centralized monitoring and management can be carried out in the communication network OMRON H7AN-E2DM AC100-240.
Wide 45mm miniaturization, simple set to the DIN guide.
H7AN-E2DM AC100-240 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=H7AN-E2DM AC100-240&select=5