Optical system: positive and negative radiation.
Detection distance: 20 positive and negative 1mm.
Beam shape: linear beam.
Beam diameter: 1.0mm * 20 m.
Resolution: 0.25 M.
Cable length: 0.5m. Output: SPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white H3DE-S1 AC/DC24-230 Price.
Item: Momentary operation (Self-resetting)
H3DE-S1 AC/DC24-230
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads H3DE-S1 AC/DC24-230 Price.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1 . Shape: round.
Protection structure: IP40.
Action: instantaneous.
Operation Department color: red.
Column length 18mm, circular F8 series.
High brightness and with uniform light.
Round type easy opening.
Small and operation feel good. Type: H7CX-A Series.
Classification: Preset counter H3DE-S1 AC/DC24-230 Price.
Configuration: 1-stage preset counter; Total and preset counter.
External connections: Screw terminals .
Settings: 1-stage.
Display digit: 4 digits.
Outputs: Transistor output (SPST).
Power supply voltage: 12 to 24 VDC.
Ultra-compact Counter Provides More,
Complete Functionality.
Basic Features.
Short body with depth of only 59 mm (for 12 to 24-VDC Models with,
Screw Terminals).
Better readability with character height of 12 mm on 4-digit models,
and 10 mm on 6-digit models.
The present value display characters can be switched between red,
green, and orange.
Safety and Reliability.
New set value limit and counter functions have been added.
Other Features.
Front Panel can be changed to white or light gray.
New models with two tachometer inputs and two tachometer outputs have,
been added to the series. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation OMRON H3DE-S1 AC/DC24-230.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions OMRON H3DE-S1 AC/DC24-230. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
H3DE-S1 AC/DC24-230 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=H3DE-S1 AC/DC24-230&select=5