Specification: three phase 200V.
Power: 5.5KW.
Maximum output voltage: three phase AC200 ~ 240V (input voltage correspondence).
Rated voltage: three phase 240V ~ 50/60Hz AC200.
Weight: about 4kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive OMRON M2CA-7001.
The high functional specifications are concentrated in the compact
M2CA-7001
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence OMRON M2CA-7001.
Multi function input and output function.
Colorful function .
Brake transistor built-in.
Protection function. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points OMRON M2CA-7001.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply .
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Operrating modes: Flicker OFF start M2CA-7001.
Supply voltage: 110 VAC (50/60 Hz), 220 VAC (50/60 Hz).
Independent ON- and OFF-time settings. Furthermore,
combinations of long ON- or OFF-time and,
short OFF- or ON-time settings are possible.
Wide time rangess ffrom 0 M2CA-7001. 05 s to 300 h.
Easy sequence checks through instantaneous,
outputs for a zero set value at any time range.
Approved by UL, CSA, CE and CCC.
M2CA-7001 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=M2CA-7001&select=5