The application of protective tube diameter: diameter of 10mm.
A variety of high precision temperature sensor series.
On the basis of the previous M3 screw,
An additional rod like terminal corresponding to the reduced wiring working hours.
A temperature sensor is used as a thermal sensor for a thermostat OMRON H3JA-8A DC12 1S.
According to the temperature, place, the surrounding environment to be measured.
Products with various shapes, shapes, lengths and terminals
H3JA-8A DC12 1S Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters OMRON H3JA-8A DC12 1S.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy OMRON H3JA-8A DC12 1S.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0 . 2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Measuring current: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Supply voltage: 100-115 VAC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supporteed by one Relay .
SStartup lock and operating time can be set separately H3JA-8A DC12 1S.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and coommmercial CT input,
(0 to 1 A or 0 to 5 A) supported H3JA-8A DC12 1S.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.
H3JA-8A DC12 1S Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=H3JA-8A DC12 1S&select=5