LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
G3R-102PN DC12 OMRON G3R-102PN DC12
No PHOTO
OMRON G3R-102PN DC12
Input capacity: 32 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common OMRON G3R-102PN DC12.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation G3R-102PN DC12
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 100 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times OMRON G3R-102PN DC12.
Weight: 210 g max.
Expansion functions: No .
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector OMRON G3R-102PN DC12.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing .
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Main contacts: DPST-NO.
Auxiliary contact: None.
Number of input channels: 1 channel or 2 channels.
Reset mode: Manual reset.
Input type: + common.
Rated voltage: 24 VAC/VDC.
Ultra Slim Safety Relay Unit.
Models of width 17.5 mm available with 2 or 3 poles. Models.
of width 22.5 mm with 3 poles also available.
Conforms to EN standards. (TÜV approval).
DIN track mounting possible. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, connvenient to check tthe state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV G3R-102PN DC12.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput G3R-102PN DC12.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
G3R-102PN DC12 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=G3R-102PN DC12&select=5


...more relevant model market price >>>>