G3M-203PL-4 DC5 OMRON G3M-203PL-4 DC5
No PHOTO
OMRON G3M-203PL-4 DC5
Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 8 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V;
1/4,000 (Settable to 1/8,000) *2.
Conversion period: 1 ms/point,
(Settable to 250 μs/point)*2 OMRON G3M-203PL-4 DC5.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S.
External connection: Removable terminal block G3M-203PL-4 DC5
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.14A; 24V, 0.14*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup OMRON G3M-203PL-4 DC5.
Analog Input Units for converting analog input,
signals into binary data .
Analog Output Units for converting binary ,
data into analog output signals. Unit type: CJ1 CPU Bus Unit.
Product Name: Controller Link Unit.
Specifications:Communications cable,
Wired shielded wisted-pair cable ;
Communications type,
Data links and message service;
Duplex support, No;
Max OMRON G3M-203PL-4 DC5. Units mountable per CPU Unit, 8;
No . of unit numbers allocated: 1.
Current consumption : 5V, 0.35A; 24V,--.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an FA,
network that can send and receive,
large amounts of data easily,
and at high speed.
The Controller Link supports data,
links that enable sharing,
data between PLCs and computers,
and a message service that enables,
sending and receiving data whenever required.
Systems can be flexibly built by using Repeater,
Units to enable T-branches, long-distance wiring,
and converting part of the network to optical cable. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, tto see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV G3M-203PL-4 DC5.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm fflexible contact output G3M-203PL-4 DC5.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
G3M-203PL-4 DC5 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=G3M-203PL-4 DC5&select=5


...more relevant model market price >>>>
Related products