V600-H14-1 OMRON V600-H14-1
No PHOTO
OMRON V600-H14-1
Sensing method: Retro-reflective with MSR function.
Connection method: Pre-wired M8 connector.
Sensing distance: 3 m (150 mm).
Model: PNP output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models OMRON V600-H14-1.
Mechanical axis and optical axis offset of less than ±2 V600-H14-15° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Size: 48 x 96mm.
Control output 1: relay.
Auxiliary (alarm) output: 4 OMRON V600-H14-1.
Transfer output: have.
Event input: 4.
Communication: RS-485 .
Disconnection detection: 2.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility OMRON V600-H14-1.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set .
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control. Model: CPM2C-32CDT1C-D. CPU Unit: Units with 32 I/O points.
2 Fujitsu connectors.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: --.Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked eeasily because operation time,
is indicated from the start of operation V600-H14-1.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeenccy, basic,
frequency, and load conditions V600-H14-1. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
V600-H14-1 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=V600-H14-1&select=5