Actuator: Plunger.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts WLCA32-043.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever
WLCA32-043
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties WLCA32-043.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13) .
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Actuator: One-way roller arm lever (vertical).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards WLCA32-043.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms .
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Classification: Standard.
Contact gap: G (0.5 mm).
Actuator: Slim spring plunger.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series of standard models for micro loads is available.
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.070 A; 60 Hz, 0.060 A .
Rated input: 50 Hz, 13 W ; 60 Hz, 11 W .
Rated rotational speed: 50 Hz, 2550 r/min; 60 Hz, 3050 r/min.
Maximum flow rate: 50 Hz, 0.9 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 49.0 Pa; 60 Hz, 68.6 Pa.
Noise: 50 Hz, 33 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 ttype) and metal-bladeed models,
(28 type) included in series OMRON WLCA32-043.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffieed safety standards depend on the,
product OMRON WLCA32-043. Check the information given for available models of Axial fans and,
the information in Characteristics.
WLCA32-043 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=WLCA32-043&select=5